The no!no! Micro is a hair removal treatment device that uses advanced Thermicon technology for home use to remove hair and the potential to reduce hair regrowth following use over a period of several months. This kit is suitable for men and women and for most skin types, hair types and hair colors.

The no!no! Micro device uses advanced Thermicon technology that was developed on the principle of sending heat signals to the hair. When applied to hair, this heat instantly removes hair. When used consistently over several months time, Thermicon technology has the potential to reduce the regrowth of hair. Thermicon uses heat and not light, unlike lasers or IPLs, therefore, it is color blind to hair color and skin type making it a suitable for hair removal treatment for everyone. no!no! Micro has one treatment level, so it is very easy to use.

Hair Removal Device Set Includes

  • no!no! Micro Hair Removal Device
  • Narrow Thermicon Tip
  • Wide Thermicon Tip
  • Large Buffer
  • Cleaning Brush
  • Power Adapter
  • Storage Bag
  • Getting Started Guide

Hair Removal Device Benefits

  • Virtually no pain, unlike lasers or waxing
  • Affordable - a fraction of the cost laser treatments or repeated waxing treatments
  • Easy to use - just glide over skin where you want to remove and treat hair
  • Smooth results - no nicks, cuts, razor bumps or ingrown hairs
  • Long-lasting - get weeks of lasting results, with continued use
  • Over time see a reduction in hair regrowth
  • Use on your legs, face, underarms or most body parts where hair can grow
  • For all hair types and skin colors
  • Small and portable - use at home or when you travel - storage bag easily stores your device and extras all in one place
  • Narrow Thermicon tip is used to help remove and treat hair on smaller and more sensitive areas, such as the face and bikini line
  • Wide Thermicon tip is used to help remove and treat hair on large areas such as arms, legs, chest and back
  • The buffer helps exfoliate, helps remove treated hair and helps leave your skin feeling smooth
  • Getting Started guide provides useful info on how to use your device, as well as important safety tips
  • Cleaning brush helps keep the thermicon tips and rollers clean to lower the risk of malfunction and prolong the life of the tips
  • Power source voltage: 7.4 V 680 mAh
  • Made in China

Please see the Usage tab for how to use information.

How To Use

Hair Removal Device: Read this entire Getting Started guide completely before using the device to ensure safety and results.

Make sure the device is charged. Remove the cap.

Choose the Thermicon tip based on what area you are treating. Use the narrow tip for the face, bikini or underarm and the wide tip for larger areas like legs, arms and back. Insert the Thermicon tip into the no!no! device.

Turn on the device by pushing the button on the top. Glide the no!no! device across your skin over the hair (you must have at least some "stubble" for the device to work) in the opposite direction of the hair regrowth. Expect to smell the hair being treated - that means it is working! Glide no!no! at approximately a 90 ° angle with the Roller flat against your skin and the logo facing in the direction you are treating. Glide one way only in the direction of the logo. Do not go back and forth. It is best to glide towards your body against the grain of the hair growth. However, if it is more comfortable you may glide in other directions, but always in the direction of the Status Screen. Use a steady, smooth and even motion. If you move too slowly, the device will not activate; if you move too fast, you will not achieve optimal results. When gliding at the proper speed the blue light will be steady. A blinking or flickering blue light indicates that you may be moving too slowly. Once your movement has been adjusted, the blue light will remain steady.

Do not press down too hard on your skin. You may need to go over an area more than once; 4-6 passes may be enough. If the skin is not uncomfortably warm, you may continue. If there is still hair left after buffing and your skin is too warm, wait a few minutes to return to the area. Try to remove all of the hair. Buff the treated hair off. If any hair remains, repeat the process.

Note: not for use on sensitive areas and if you feel any discomfort, stop use of device immediately. For best results, use as often as a razor for first 4-6 weeks, and then use as needed.

Do not use around eyes. Do not use on genitals or nipples. If you feel any discomfort during use STOP and give your skin a rest.

Thermicon Tips: Inserting the Thermicon Tip - make sure the device is turned off. Hold no!no! in one hand and the Tip in the other. Make sure both logos are facing the same direction and line up the posts in the socket with the holes in the Thermicon Tip. Gently push into place. Removing the Thermicon Tip - grasp the Tip by both sides. Gently pull the Tip out of the socket. Make sure the Thermicon Tip is placed properly into the socket before treatment.

Never use a Thermicon Tip if the wire is bent or torn. Replace the Thermicon tip if the light turns red, if it is no longer working efficiently, if the wire is damaged in any way or if the Thermicon Tip Icon is blinking and no more bars appear on the Status Screen. Level of usage will determine when to replace the Thermicon Tips.

Large Buffer: Hold the buffer, firmly rub the buffer in a circular and/or back and forth motion over the treated area. Replace buffer when the pad feels smooth and it is no longer buffing effectively.

Cleaning Brush: Use the brush to gently brush the inside of the Thermicon Tips clean.

Care: Do not use any liquid to clean the device, Thermicon Tips or Rollers. Keep the Thermicon Tips and Rollers clean to lower the risk of malfunction and prolong the life of the Tips.

1. Turn off your no!no!.

2. Remove the Thermicon Tip.

3. Gently brush the inside of the Tips clean.

4. Brush debris out and away from the socket and roller. If any hair or debris falls into the socket, this may cause no!no! to malfunction. Brush any particles out of the socket before beginning a treatment.